7,300 sq m of triple glazed low emissivity
coated clear glass, incoporating shading devices
Heat insulation:
Average value = 0.7-0.8 W/m_.k
Angle of glass front inclination:
31 degrees
Diameter of circular glass facade:
45m
Environmental strategy:
Windows open for natural ventilation,
bore hole water cooling, heat recovery, displacement ventilation system,
no chillers required
Energy consumption:
Energy consumptions for GLA's environmental systems is less than
half levels in DETR good practice office guide.
The radical shape of the building minimses the surface area (approx
25 per cent less than an equivalent rectangular building). is self
shading and the high performance facade ensures excellent energy
efficiency.
Electrical consumption:
Greatly reduced as a result of using
cold ground water instead of refrigeration to air condition the building.
Saving use of mains water, the water is extracted through two bore
holes from the water table beneath London and is used to cool the
building and is then used for flushing the toilets.
Architect:
Foster and Partners
Construction Managers:
MACE
Structural, services, facade, fire, communications
and acostics engineers: